{"product_id":"kivo-bpv001-angled-automatic-bypass-valve","title":"KIVO BPV001 Angled Automatic Bypass Valve","description":"\u003cdiv style=\"color:#233746;font-size:16px;line-height:1.7;\"\u003e\n\u003cdiv style=\"background:#f4f6f5;border-left:4px solid #1a636e;padding:16px 20px;margin:0 0 24px;\"\u003e\n\u003ch3 style=\"margin:0 0 8px;font-size:19px;color:#0e2130;\"\u003eConnection size \u0026amp; installation fit\u003c\/h3\u003e\n\u003cp style=\"margin:0;\"\u003eAngled configuration. Confirm the required pipe connection and installation clearance with KIVO before ordering.\u003c\/p\u003e\n\u003cp style=\"margin:8px 0 0;font-size:14px;\"\u003ePipe connection size is not the overall product size. For a dimensioned drawing or tight-space installation, email \u003ca href=\"mailto:sales@rockensupplygroup.co.uk\"\u003esales@rockensupplygroup.co.uk\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe KIVO Angled Automatic Bypass Valve helps maintain the minimum water flow required in sealed central heating systems. It opens automatically when the differential pressure reaches the selected setting, allowing water to circulate through the bypass as flow through the heating circuit becomes restricted.\u003c\/p\u003e\n\u003cp\u003eWith an adjustable differential pressure range of 0.1–0.5 bar, the valve can be set to suit the system’s requirements, helping protect boilers and circulation pumps from insufficient flow and excessive differential pressure. Its angled configuration suits pipework requiring a change of direction, including suitable floor-mounted installations. Manufactured from CW617N brass, it offers durable construction for reliable long-term service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eAngled Configuration:\u003c\/strong\u003e Suits pipework requiring a change of direction, including suitable floor-mounted installations.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eAdjustable Differential Pressure:\u003c\/strong\u003e Set the bypass opening pressure between 0.1 and 0.5 bar to suit system requirements.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eAutomatic Bypass Operation:\u003c\/strong\u003e Opens as differential pressure rises to help maintain the required minimum flow.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eBoiler and Pump Protection:\u003c\/strong\u003e Helps reduce strain caused by restricted circulation and excessive differential pressure.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eDurable Brass Construction:\u003c\/strong\u003e CW617N brass body provides strength and durability for long-term service.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e Suitable for sealed domestic and commercial central heating systems.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.5;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#0e2130;color:#fff;text-align:left;padding:12px;border:1px solid #dce4e7;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"background:#0e2130;color:#fff;text-align:left;padding:12px;border:1px solid #dce4e7;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eKIVO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eCW617N Brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eValve Type\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eAngled Automatic Bypass Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003e10 bar (145 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eAdjustable Differential Pressure Range\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003e0.1–0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eWorking Temperature Range\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003e0°C to 90°C (32°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border:1px solid #dce4e7;vertical-align:top;\"\u003eEN 1254-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e","brand":"KIVO","offers":[{"title":"Default Title","offer_id":58656863551869,"sku":"X0037.022.0004-0209","price":8.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0957\/1405\/0429\/files\/Codex_2026_9_9_22_08_37.png?v=1788988261","url":"https:\/\/www.rockensupplygroup.co.uk\/products\/kivo-bpv001-angled-automatic-bypass-valve","provider":"Rocken Supply Group Store","version":"1.0","type":"link"}